Aeroqual Series 500 Handheld Air Quality Monitor

One meter, many sensor heads. You unclip the head and clip on a different one depending on what you are measuring. There is nothing to set up when you swap. The calibration is stored in each head.

This is the meter you use for spot checks, for finding a problem, and for checking that a system is doing what it should. 

Made by Aeroqual of New Zealand. Contact us for discounted pricing.

Aeroqual Series 500 Handheld with Ozone Sensor Head

Aeroqual Series 500 Specifications

What Detail
Base unit Aeroqual Series 500 (S500) handheld monitor
Sensor heads available More than 25 heads are made by Aeroqual. We supply: ozone, TVOC chemicals, PM2.5 and PM10 dust, carbon monoxide, carbon dioxide, nitrogen dioxide and formaldehyde and others.
How it works One head at a time. Swap the head and the meter reads that gas. A small fan pulls air into the head for a steadier reading.
Calibration Each head is calibrated at the factory and comes with a calibration certificate. Aeroqual recommends recalibrating after one year and replacing the head after two years.
Important Details Works in: -5 to 45 °C, 0 to 95% humidity (no condensation) Readings shown: live, lowest, highest and average Alarms: high and low alarms you can set Data logging: up to 8,188 readings, downloaded by USB to free Windows software Outputs: 0 to 5 V analogue output Units: ppm or mg/m³
Size, weight and battery 195 x 122 x 54 mm with a head fitted. Under 460 g with head and battery. Rechargeable lithium-ion. Lasts a full working day. Charger included (100 to 250 V AC).

Which Ozone Head Do I Need?

Head Range Accuracy (factory) Best for
OZU 0 to 0.15 ppm Plus or minus 0.005 ppm Very low outdoor ozone levels
OZL 0 to 0.5 ppm Plus or minus 0.008 ppm up to 0.1 ppm Low ozone levels, mainly outdoors
EOZ 0 to 10 ppm Plus or minus 0.01 ppm + 7.5% Indoor ozone work, including checking a room after an ozone treatment
EOZH 0 to 30 ppm Plus or minus 0.05 ppm + 10% High ozone levels, such as during an ozone treatment

Figures from Aeroqual. Aeroqual advises the EOZ and EOZH heads for indoor use. The OZU and OZL heads can be affected by chemicals (VOCs) in indoor air.

Where the Aeroqual Series 500 Is Used

  • Checking ozone has dropped before people go back into a room after an ozone treatment.

  • Spot checks in offices and buildings.
  • Checking a new air treatment system after it is installed.

  • Checking ozone near equipment that makes ozone, like ozone generators and some air cleaners.

  • Short-term logging in one spot, using the optional wall bracket and mains power.
  • Finding the source of a complaint.
  • Checking a treatment worked.

How the Aeroqual Series 500 Works

  1. Clip the sensor head for your gas onto the top of the meter.
  2. Switch on. A small fan pulls air into the head.
  3. The screen shows the reading in ppm or mg/m³.
  4. Set a high and low alarm if you want a warning.
  5. Plug into a Windows computer by USB to download the logged readings.

Warranty on the Aeroqual Series 500

Aeroqual gives a one-year warranty from the date of shipping. It covers defects in parts and workmanship. Calibration, batteries and fans are not covered. Warranty claims for products that we sell are handled in Singapore by ProMedUSA.

Aeroqual Series 500 Questions and Answers

Need the Right Sensor for Your Air Quality Check?

The Aeroqual Series 500 can be configured with different sensor heads for ozone, VOCs, particulate matter, COâ‚‚, formaldehyde and other gases. Tell us what you need to measure and where you need to measure it, and our team can help you choose the appropriate sensor head and setup.

For more details, go directly to the Aeroqual website.